Role of Tissue-Doppler Imaging to Assess Left Ventricular Function in Patients with Right Ventricular Pacing

AUTHORS

AR Moarref 1 , Ebrahim Fallahzadeh 2 , * , J Zamani 1 , KS Najib 1

1 Department of Cardiology,Shiraz University of Medical Sciences, Fars, Iran

2 Assistant Professor of Department of Internal Medicine, Nemazee Hospital, Shiraz University of Medical Sciences, [email protected], Fars, Iran

How to Cite: Moarref A, Fallahzadeh E, Zamani J, Najib K. Role of Tissue-Doppler Imaging to Assess Left Ventricular Function in Patients with Right Ventricular Pacing, Iran Red Crescent Med J. Online ahead of Print ; 11(2):193-198.

ARTICLE INFORMATION

Iranian Red Crescent Medical Journal: 11 (2); 193-198
Article Type: Brief Report
Received: January 15, 2008
Accepted: August 1, 2008

Crossmark

CHEKING

READ FULL TEXT
Abstract

Background: Right ventricular apical (RVA) pacing has been reported to impair diastolic and systolic function. These changes were usually studied by conventional echocardiography, while tissue-doppler imaging (TDI) has provided a new way to evaluate global and regional systolic left ventricular (LV) function and abnormal LV relaxation. We designed this study to evaluate the changes of TDI-derived indices of asynchrony after RVA pacing.

 

Methods: We followed 41 patients with LV ejection fraction (LVEF) ³45% and LV end-diastolic dimension (LVEDD) £ 56 mm who underwent single- or dual-chamber RVA pacemaker implantation for performing pacemaker analysis and second 2-dimensional (2D) echocardiography and TDI, at least 4.2 months later. 2D measurements included LVEDD, LV end-systolic dimension (LVESD), left atrial (LA) volume and septum to lateral asynchrony, while TDI measurements were the peak velocities of myocardial shortening (Sm) and early myocardial relaxation (Em).

 

Results: Considering the exclusion criteria, 20 patients entered the study with the mean age of 66.05 years and follow-up of 7.86 months (4.20-12.25). The reduction of Sm, Em and LVEF, and the increment of LVEDD, LVESD, septum to lat asynchrony and LA volume were statistically significant. Changes of all these parameters, however, were independent of pacing duration, frequency or mode (single- or dual- chamber).

 

Conclusions: RVA pacing has deleterious effects on both LV systolic and diastolic parameters of not only conventional echocardiography but also TDI even in patients with normal LV function. Furthermore, LA volume increases significantly.

Keywords

Tissue-doppler imaging Left ventricular function Right ventricular pacing Left atrial volume Conventional echocardiography

© 0, Author(s). This is an open-access article distributed under the terms of the Creative Commons Attribution-NonCommercial 4.0 International License (http://creativecommons.org/licenses/by-nc/4.0/) which permits copy and redistribute the material just in noncommercial usages, provided the original work is properly cited.

Full Text

Full text is available in PDF

COMMENTS

LEAVE A COMMENT HERE: